Standard Equipment Specs

STANDARD RACK SPECIFICATIONS

AJXR 100 Series

AJM 150 Series

AJMR & AJSR 159 Series

Standard Sizes

Height: 72”

Width: 22.31”

Three (3) standard depths: 26", 30", 36"

Height: 72”

Width: 22.31”

Three (3) standard depths: 26", 30", 36"

Height: 72”

Width: 24”

Three (3) standard depths: 26", 30", 36"

Payload

Up to 500 lbs.

Up to 1200 lbs.

Up to 1600 lbs.

Material

2500 Series aluminum extrusions

6500 Series aluminum extrusions

9000 Series aluminum extrusions

Shock Protection

Light Duty

Medium/Heavy Duty

Extreme Heavy Duty

Shock & Vibration Protection

Provides a lightweight, space saving rack for protection

from rain, dust and surface impact

Delivers a rack with good vibration protection using shock mounts

Delivers maximum level of shock and

vibration protection, including MIL-specs: MIL-STD-901D, MIL-STD-810 and MIL-STD-167

Uses

Semi-Fragile Medical Equipment, Radios and Amplifiers,

Field Deployed Test Equipment

Industrial Applications, Military Rapid Deployment, Field-Deploy Applications,

Control Consoles/Panels, Broadcast & Television Communications Equipment

Military Rapid Deployment, Memory Storage Devices,

Precision Lab Equipment, Calibrated Diagnostic / Testing Gear,

Aerospace Instrumentation

Configuration

Fully configurable 

(COTS & customizable)

RACK & ENCLOSURE OPTIONS

Panels (Type & Thickness)

  • Bottom – Full – 0.25 inches
  • Side Panel – L/R – .09 inches
  • Side Panel – L/R – .12 inches
  • Side Panel – Louvered – L/H – .09 inches
  • Side Panel – Louvered – R/H – .09 inches
  • Side Panel – Louvered – L/H – .12 inches
  • Side Panel – Louvered – R/H – .12 inches
  • Rear Panel – .09 inches
  • Rear Panel – .12 inches
  • Rear Panel – Louvered – .09 inches
  • Rear Panel – Louvered – .12 inches

EMI/RFI

  • EMI/RFI Configuration
  • EMI/RFI Gasketing

EIA RETMA Rails

  • (2) Front RETMA Rails
  • (2) Rear RETMA Rails
  • (2) Intermediate RETMA Rails
  • (2) Rear Back-up Bars

Doors

  • Front Opening Door – L/H or R/H
  • Rear Opening Door – L/H or R/H

Have a standard design you want customized to meet your needs?

Talk to an Engineer